• Lunes a jueves 9h a 14h & 15h a 19h • Viernes 9h a 14h
Table of manoeuvres Forsa "PNG-20' 230V for one- or two-bladed swing and swing doors
Referencia: MAN320
€181.00
IVA excluido

219,01 €

IVA incluido

Table of manoeuvres Forsa "PNG-20' 230 V for tilting and swinging doors of 1 or 2 sheets.

Box PNG-20 is provided with a socket to insert radio frequency and traffic light receiver cards.

Quantity

 

We ship your order in 24/7 hours

 

Payment by credit card, bank transfer, Paypal or Bizum

 

Free shipping to the peninsula

Control panel Forsa "PNG-20" 230V for 1 or 2 leaf overhead and swing doors.

The PNG-20 box is provided with a socket for inserting radio frequency and traffic light receiver cards.

FUNCTIONS

  • Open (ABR.): Contact normally open to open. If pressed during the closing manoeuvre, it stops and opens.
  • Close (CER.): Contact normally open to close. If pressed during the opening manoeuvre, it stops and closes.
  • Alternate (ALT.): Normally open contact to open and close. First press, opens, second, (if you haven't reached the end of the path) stops, and third, closes.
  • Stoppage (STOP): Contact normally closed. He stops the manoeuvre while waiting for a new order. If not in use, set option 5 of the input selector to ON.
  • Pedestrian (PEA.): Normally open contact for single-leaf opening (total or partial).
  • Limit switches (FCC1 / FCA1 / FCC2 / FCA2): contacts normally closed to mechanically indicate the end of the opening and closing path. If not in use, set options 6 and 7, 8 and 9 of the input selector to ON. 0
  • Safety Band (BS. CE/ BS.AB.): Resistive contact for resistive safety band. It acts in closing, causing unemployment and investment. It acts on the opening, causing stoppage and reversal of 1s. If not in use, set options 3 or 4 of the input selector to ON.
  • Safety contact (S.CER / S.ABR): Normally closed contact type photocell or magnetic detector. It acts at the opening and closing, causing stoppage and reversal. If not used, set options 1 or 2 of the input selector to ON.
  • Garage light contact (GAR. LIGHT): Voltage-free contact for activation of an automatic light (max 100W at 230Vac).
  • Flash Lamp Contact (FLASH): Contact kept voltage-free for activation of a flash lamp (max. 250V / 12A).
  • Electric lock (ELECTRO): Output timed to 2 seconds to activate an electric latch max. 12 Vdc / 1 A).
  • 24Vac output: allows any equipment to be powered at a voltage of 24Vac with a maximum consumption of 0.75A.
  • Self-test output (TEST SEC.): 24Vac output that allows self-testing of safety elements.

SPECIFICATIONS

MANUAL

Instruction manual FORSA PNG

MAN320

Specific References

Download

MANUAL FORCE PNG-12

Download (834.53KB)

You might also like

Open source plug-in receiving card - Figure 1
AERF
Receiver cards
Open source plug-in receiver card 433 MHz
€32.50

Envios 24/72h

Envios gratuitos a peninsula

pedidos superior a 150€

Calidad al mejor precio

Tenemos las mejores marcas del

mercado en automatismos

Pago seguro

Métodos de pago por transferencia

tarjeta de crédito/débido o Paypal

Soporte técnico

Te asesoramos antes y después

de realizar tú pedido