Table of manoeuvres Forsa "PNG-20' 230V for one- or two-bladed swing and swing doors
Referencia: MAN320
€181.00
IVA excluido
219,01 €
IVA incluido
Table of manoeuvres Forsa "PNG-20' 230 V for tilting and swinging doors of 1 or 2 sheets.
Box PNG-20 is provided with a socket to insert radio frequency and traffic light receiver cards.
We ship your order in 24/7 hours
Payment by credit card, bank transfer, Paypal or Bizum
Free shipping to the peninsula
Control panel Forsa "PNG-20" 230V for 1 or 2 leaf overhead and swing doors.
The PNG-20 box is provided with a socket for inserting radio frequency and traffic light receiver cards.
FUNCTIONS
- Open (ABR.): Contact normally open to open. If pressed during the closing manoeuvre, it stops and opens.
- Close (CER.): Contact normally open to close. If pressed during the opening manoeuvre, it stops and closes.
- Alternate (ALT.): Normally open contact to open and close. First press, opens, second, (if you haven't reached the end of the path) stops, and third, closes.
- Stoppage (STOP): Contact normally closed. He stops the manoeuvre while waiting for a new order. If not in use, set option 5 of the input selector to ON.
- Pedestrian (PEA.): Normally open contact for single-leaf opening (total or partial).
- Limit switches (FCC1 / FCA1 / FCC2 / FCA2): contacts normally closed to mechanically indicate the end of the opening and closing path. If not in use, set options 6 and 7, 8 and 9 of the input selector to ON. 0
- Safety Band (BS. CE/ BS.AB.): Resistive contact for resistive safety band. It acts in closing, causing unemployment and investment. It acts on the opening, causing stoppage and reversal of 1s. If not in use, set options 3 or 4 of the input selector to ON.
- Safety contact (S.CER / S.ABR): Normally closed contact type photocell or magnetic detector. It acts at the opening and closing, causing stoppage and reversal. If not used, set options 1 or 2 of the input selector to ON.
- Garage light contact (GAR. LIGHT): Voltage-free contact for activation of an automatic light (max 100W at 230Vac).
- Flash Lamp Contact (FLASH): Contact kept voltage-free for activation of a flash lamp (max. 250V / 12A).
- Electric lock (ELECTRO): Output timed to 2 seconds to activate an electric latch max. 12 Vdc / 1 A).
- 24Vac output: allows any equipment to be powered at a voltage of 24Vac with a maximum consumption of 0.75A.
- Self-test output (TEST SEC.): 24Vac output that allows self-testing of safety elements.
SPECIFICATIONS
MANUAL
You might also like
icon
Envios 24/72h
Envios gratuitos a peninsula
pedidos superior a 150€
icon
Calidad al mejor precio
Tenemos las mejores marcas del
mercado en automatismos
icon
Pago seguro
Métodos de pago por transferencia
tarjeta de crédito/débido o Paypal
icon
Soporte técnico
Te asesoramos antes y después
de realizar tú pedido