Kit V2 Calypso 500 for 2-leaf swing door
Automation kit for two-leaf residential beating doors, composed of two irreversible electromechanical engines V2 230 V Calypso 500.
Designed to automate sheets up 3 meters long and 500 kg weight per leaf, as long as the geometry, structure and dormas of the door installation are compatible.
Featured features
- Complete kit to automate a swing door two leaves.
- Two irreversible engines V2 CALYPSO 500.
- For 3 m and 500 kg each.
- Feeding the engines 230 V - 50 Hz.
- The same version can be installed on the right or left sheet.
- Manual unlocking system by key to use the door in case of lack of current.
- Two controls Rolling Code of 433 MHz included.
Choose the maneuver box
The kit is available with three different maneuvers. Select the desired version before adding the product to the cart.
FlexY2 option - Ref. ZV6187
Maneuvering 230 v analog with 433.92 MHz receiver built-in MHz, for one or two swinging engines.
- Radio receiver 433.92 MHz integrated.
- Ability to memorize up 240 personal Estabilors Pass compatible.
- You do not need an additional MR2 receiver to use the included controls.
- Regulation of power, working time, pause and delay between leaves by potentiometers.
- Programming functions using DIP switches.
- Total opening and pedestrian opening.
- Configurable automatic closure.
- Slow down at the end of opening and closing maneuvers.
- Entrance for photocell safety.
- Input for traditional or resistive security band of 8.2 kΩ.
- Tickets for late opening and closing endings.
- Test compatible safety devices before maneuver.
- Exit for signaling lamp.
- Contact to activate a courtesy light.
- RJ45 connector for compatible Prog2 programmer.
- Housing with protection degree IP55.
Option City 11 - Ref. ZV6181
Maneuvering analog of 230 V for one or two engines, with regulation by means of Potentiometers and DIP switches.
- Regulation of power and operating times through potentiometers.
- Programming functions using DIP switches.
- Total opening and pedestrian opening.
- Configurable automatic closure.
- Regulation of the delay between the two leaves.
- Entrance for photocells and safety band.
- Test compatible safety devices.
- Output for 12 V electroning.
- Exit for signaling lamp.
- Contact for courtesy light.
- Connector for plug-in receiver of the MR series.
- Housing with protection degree IP55.
Option CX EVO 1 - Ref. ZV61726
Maneuvering digital 230 V with Screen, indicated for facilities that need a more complete configuration and greater control over the operation of the door.
- Screen for programming and viewing of the status of the entries.
- Control of one or two motor 230 V motors.
- Regulation independent of the power of each engine.
- Automatic learning of work times.
- Detection of obstacles by controlling motors.
- Control of the correct order of closure of the two leaves.
- Total opening and pedestrian opening.
- Independent entries for two types of photocells and two types of safety bands.
- Test of photocells, safety bands and Triac before each maneuver.
- Tickets for career endings or compatible coders.
- Output for 12 V electroning.
- Exit for signaling lamp of 230 V.
- Connector for plug-in receiver of the MR series.
- USB connector for programming, diagnosis and update using the manufacturer's compatible tools.
- ADI interface for compatible optional modules.
- Housing with protection degree IP55.
Content of the FlexY2 version
Kit ZV6187
- 2 engines V2 CALYPSO 500 of 230 V, with a maximum drag racing of 500 mm.
- 1 maneuver box V2 FLEXY2 analog of 230 V, with a receptor of 433.92 MHz incorporated.
- 2 tX TOH2 emitters Rolling Code of 433 MHz and 2 channels.
Content of the City 11 version
Kit ZV6181
- 2 engines V2 CALYPSO 500 of 230 V, with a maximum drag racing of 500 mm.
- 1 cITY 11 maneuver box analog of 230 V.
- 1 mR2 plug-in receiver of 433 MHz.
- 2 tX TOH2 emitters Rolling Code of 433 MHz and 2 channels.
Content of the CX EVO 1 version
Kit ZV61726
- 2 engines V2 CALYPSO 500 of 230 V, with a maximum drag racing of 500 mm.
- 1 maneuver box CX EVO 1 digital 230 V with screen.
- 1 mR2 plug-in receiver of 433 MHz.
- 2 tX TOH2 emitters Rolling Code of 433 MHz and 2 channels.
Engine measurements V2 CALYPSO
Before performing the installation, check that the available dimensions and the door fixing dimensions are compatible with the engine.

Technical characteristics of the Calypso 500
| Model |
V2 CALYPSO 500-230V |
| Engine code |
22G003 |
| Maximum length of each sheet |
3 m |
| Maximum weight of each sheet |
500 kg |
| Feed |
230 V - 50 Hz |
| Empty absorption |
0.8 A |
| Absorption with load |
1.2 A |
| Electric power |
250 W per motor |
| Capacitor |
8 μF |
| Opening time 0 ° -90 ° |
25 s |
| Maximum drag |
500 mm |
| Trawl |
0,016 m / s |
| Maximum |
2300 N |
| Operating temperature |
-30 ° C to +50 ° C |
| Degree |
IP44 |
| Work cycle |
30% |
| Weight of each engine |
6.8 kg |
Unlocking
In case of lack of current, each engine can be unlocked manually by entering the supplied key in the front lock and performing half turn. To restore automatic operation, the key must be returned to the closing position.
Elements not included
Important before buying
Unless expressly indicated in another option or promotion, the kit does not include:
- Fotocells and other security devices.
- Signaling lamp.
- Electrocerradura.
- Key selector, pushbuttons or other opening devices.
Necessary checks
Compulsory professional installation
- The electrical and mechanical installation must be performed by qualified personnel.
- The door must have central and lateral stops.
- The leaves must be scrolled without friction, being properly balanced and having a solid structure.
- The installation dimensions indicated by the manufacturer must be respected.
- For leaves of more 2 meters, the manufacturer indicates that it is necessary to install a electrocerradura to ensure effective closure.
- The limits of 3 m and 500 kg should not be interpreted independently: the suitability depends on the weight, longitude, structure, wind resistance and installation geometry.
- Automation must incorporate the security devices required by the regulations and by the analysis of risks of the installation.